Si3216
Rev. 1.0 9
Not Recommended
f
o
r N
e
w
D
e
si
g
n
s
Table 4. AC Characteristics—Narrowband Audio Mode
(V
DDA
, V
DDD
= 3.13 to 5.25 V, T
A
= 0 to 70 °C for K-Grade, –40 to 85 °C for B-Grade)
Parameter Test Condition Min Typ Max Unit
TX/RX Performance—Narrowband Audio Mode
Overload Level THD = 1.5% 2.5 V
PK
Single Frequency Distortion
1
2-wire – PCM or
PCM – 2-wire:
200 Hz–3.4 kHz
——45dB
Signal-to-(Noise + Distortion) Ratio
2
200 Hz–3.4 kHz
D/A or A/D 16-bit
Active off-hook and OHT,
any Zac
Figure 3
Audio Tone Generator
Signal-to-Distortion Ratio
2
0 dBm0, Active off-hook and
OHT, any Zac
45 dB
Intermodulation Distortion –41 dB
Gain Accuracy
2
2-wire to PCM, 1014 Hz –0.5 0 0.5 dB
PCM to 2-wire, 1014 Hz –0.5 0 0.5 dB
Gain Accuracy Over Frequency Figure 5,6
Group Delay Over Frequency Figure 7,8
Gain Tracking
3
1014 Hz sine wave, refer-
ence level –10 dBm
signal level:
3 dB to –37 dB –0.25 0.25 dB
–37 dB to –50 dB –0.5 0.5 dB
–50 dB to –60 dB –1.0 1.0 dB
Round-Trip Group Delay at 1000 Hz 1100 µs
Gain Step Accuracy –6 dB to 6 dB 0.017 0.017 dB
Gain Variation with Temperature All gain settings –0.25 0.25 dB
Gain Variation with Supply V
DDA
=V
DDA
= 3.3/5 V ±5% –0.1 0.1 dB
2-Wire Return Loss 200 Hz–3.4 kHz 30 35 dB
Transhybrid Balance 200 Hz–3.4 kHz 30 dB
Notes:
1. The input signal level should be 0 dBm0 for frequencies greater than 100 Hz. For 100 Hz and below, the level should be
–10 dBm0. The output signal magnitude at any other frequency will be smaller than the maximum value specified.
2. Analog signal measured as V
TIP
– V
RING
. Assumes ideal line impedance matching.
3. The quantization errors inherent in the µ/A-law companding process can generate slightly worse gain tracking performance
in the signal range of 3 dB to –37 dB for signal frequencies that are integer divisors of the 8 kHz PCM sampling rate.
4. The level of any unwanted tones within the bandwidth of 0 to 4 kHz does not exceed –55 dBm.
5. Assumes normal distribution of betas.