AE/LZB 119 1894 R1A SOFTWARE SET-UP PROCEDURE
40
NOTE
The serial control data link between the PC and the
CEC/IMC CIM must be operational before the
console’s GUI will completely start. If not, the GUI
program’s “Initializing, please wait…” message
box will remain until the link is restored or the
program(s) terminates. If this problem occurs,
correct the serial control data link problem before
continuing with the following database
initialization procedures. Although not required at
this point, the console application may be
terminated by “ending” the Dispatch Manager
program using the Windows NT Task List. Open
the Task List via a <Ctrl><Esc> keystroke from the
PC’s keyboard. On the Task List, the Dispatch
Manager program is titled “C3 Maestro Dispatch
Manager”.
Database Initialization
When the console initializes from a cold start, the
procedures presented in the following subsections should be
performed to insure proper operation. All console databases
are initialized via commands from the CEC/IMC Manager
(MOM PC). If necessary, refer to the appropriate manual
listed in Table 29 or access the CEC/IMC Manager’s on-line
help for complete operating instructions.
Table 29 – CEC/IMC Manager
Operations Guide Publication Numbers
SOFTWARE
VERSION:
V2.x
(for
DOS)
V3.x
(for
DOS)
V4.x
(for
DOS)
V5.x
(for Win-
dows NT)
PUBLICATION
NUMBER:
LBI-
38911
LBI-
39024
LBI-
39124
LBI-
39224
Basically, except for sending console configurations to
the console(s), it is assumed all CEC/IMC console-related
configurations are complete as described in the CEC/IMC
Digital Audio Switch Installation, Set-Up And
Troubleshooting maintenance manual, LBI-38938. See
"STEP 6 - CONSOLE CONFIGURATION" in LBI-38938
for complete details. Consult CEC/IMC
administrative/maintenance personnel as required.
NOTE
The following procedures are written in accordance
with CEC/IMC Manager version 5.x software
(Windows NT-based). If using earlier
CEC/IMC Manager software (DOS-based), menu
access and dialog box/screen titles will differ from
those presented in the following subsections. In this
case, if necessary, refer to the manual listed in
Table 29 or access the CEC/IMC Manager’s on-
line help for exact menu selections required to
accomplish these console-related configurations.
Sending Console User Profiles (“Setups”)
From the CEC/IMC Manager, user profile data is sent
only to a targeted console. When the target console receives
this data from the CEC/IMC Manager it will send an
acknowledgment to the CEC/IMC Manager. When this
procedure is performed, two very important parameters are
sent to the console along with the user profiles: the console’s
logic ID (LID) number and its alias.
Send user profile data to the console as follows. At this
time it is assumed the console application is running
and it is on-line with the CEC/IMC (CIM link is
operational):
1.
From the CEC/IMC Manager's Configure System
main menu, select Console Configuration. This
action will display the console configuration sub-
menu.
2.
From this sub-menu, select User Profile. The
Console User Profile Configuration dialog box
displays.
3.
Select the console’s number via the respective list
box (range = 1 to 32). Verify the selected number
matches the CIM's console assignment number
defined by the respective CIM's Controller Board
DIP switches. For example, if the console is
interfaced to CIM 3 in the CEC/IMC, select
CONSOLE 03.
4.
From the Unit ID (LID) text box, verify the
console’s unit ID number does not conflict with any
other console or radio ID number in the system.
5.
Optional: On a per setup basis (10 total), make any
required changes and save changes via the <Save>
button. Refer to the applicable CEC/IMC Manager
publication listed in Table 29 and/or the CEC/IMC
Manager’s on-line help for complete details.
6.
Send the ten user profiles/setups to the (target)
console by clicking the <Send> button.
NOTENOTE