INTERCONNECTING THE EQUIPMENT AE/LZB 119 1894 R1A
13
If COM3: Interrupt
Jumper JP3
“11” position
If any other RS-422 plug-in serial board is used the
following board configuration is recommended:
COM Port COM3
Port Address 3E8
Interrupt IRQ11
Normally, a pre-wired 100-foot (30.5 meters) cable is
supplied with the console equipment package for RS-422
control data interconnections between the CEC/IMC and a
co-located C3 Maestro console. The cable's part number is
19B804083P3. It has a female DB-25 connector on one end
for mating to the RS-422 male DB-25 connector at the PC
(see the following note). The other end is "pig-tailed" (not
terminated) so the cable's 24-gauge solid wires can be
punched down to the correct terminals at the required
CEC/IMC punch block.
If using the supplied control data cable, mate its female
DB-25 to the PC's RS-422 male DB-25 connector, route
it to the CEC/IMC, shorten the cable as required, and
punch the wires to the correct terminals. See Table 6 or
the cable's assembly diagram (page 21) for wire color
coding. Also see Figure 7A.
NOTE
If cable 19B804083P3 is utilized and the PC is
equipped with a 3PXCC2A plug-in RS-422 board
(dual ports with DB-9 connectors), a field-
fabricated DB-9-to-DB-25 adapter must be
constructed and utilized as shown in Figure 7C.
In addition, cable 19B804083P3 is not compatible
with earlier plug-in RS-422 boards used with the
C3 Maestro console system. These earlier plug-in
boards are manufactured by ICS and included
model numbers RS422AT-P and RS422I-P. They
can be easily identified by the presence of two LED
indicators visible on the rear plate.
If cable 19B802083P3 is not used but RS-422 hook-ups
are required, see Figures 4 (or 5) and 7A and/or the
manufacturer's documentation for COM port connector
pin-out details. Fabricate a cable as required and then
use it to interconnect the C3 Maestro's RS-422 control
data COM port to the appropriate CEC/IMC Data
Concentrator Card as required. Shielded cabling is
recommended. Per RS-422 specifications, cable length
should be limited to 4000 feet (1219 meters) or less.
Table 6 – Cable 19B804083P3 Color Coding
PC
RS-422
PORT
DB-25
PIN NO.
***
CONSOLE
RS-422
SIGNAL
WIRE
COLOR
(Also see
page 21)
TYPICAL
CEC/IMC
CONNECTION
IDENTIFI-
CATION *
1 cable shield n/a none **
2 TX- white/blue
CRT
01 RX-
DATA
14 TX+ blue
CRT
01 RX+
DATA
3 RX- white/orange
CRT
01 TX-
DATA
16 RX+ orange
CRT
01 TX+
DATA
7 ground white/green none **
* CEC/IMC Data Concentrator Card identification. See
customer-specific system documentation print-outs for
specific pin/terminal numbers.
** Wire not terminated at CEC/IMC punch block. Insulate
and tie back at punch block.
*** If PC is equipped with plug-in RS-422 board
3PXCC2A, see Figure 5 for DB-9 connector pin
numbers.
NOTES:
1. VIEWED FROM BACK OF COMPUTER (MALE DB-25) OR
WIRING SIDE OF MATING CONNECTOR (FEMALE
DB-25).
2. TX LINES MUST CONNECT TO "CRT" RX LINES AT
CEC/IMC CONCENTRATOR CARD OR PUNCH BLOCK, +
TO + AND - TO -.
RX LINES MUST CONNECT TO "CRT" TX LINES AT
CEC/IMC CONCENTRATOR CARD OR PUNCH BLOCK, +
TO + AND - TO -.
3. COLOR CODING INDICATES CABLE 19B804083P3 WIRE
COLORS.
13121110
25
9876
54321
14
24232221
15
201918
1716
RS-422 RX-
(WHITE/ORANGE)
RS-422 RX+
(ORANGE)
RS-422 TX-
(WHITE/BLUE)
RS-422 TX+
(BLUE)
SIGNAL GROUND
(WHITE/GREEN)
SHIELD
Figure 4 – Plug-In RS-422 Board DB-25 Connector
Pin-Out (B&B Electronics 3PXOCC1A Board)
NOTE
Do not over-tighten the screws on the DB-style
connectors.
NOTE
NOTE