SOFTWARE SET-UP PROCEDURE AE/LZB 119 1894 R1A
39
Via Windows NT (Verifying FIFO Is Enabled)
Each PC serial communication port which supports
console operation has a very important configuration
setting—“first-in-first-out” (FIFO)—which, if not
enabled, may cause erratic console operation. Some
third-party software installation programs may disable
FIFO on one or more COM ports. In addition, changes
within Control Panel’s Ports dialog box may
unintentionally disable FIFO. Verify FIFO is enabled
for COM1 thru COM3 as follows:
1. From Windows NT Program Manager, if necessary
open the Main program group by double-clicking
on its icon:
2. Open Control Panel by double-clicking its icon:
3. Execute the Ports program within Control Panel by
double-clicking on its icon:
4. If necessary, from the Ports dialog box select
COM1: in the Ports: listing.
5. Select <Settings…> and then <Advanced…>.
The Advanced Settings for COMx: dialog box
will appear (where x = selected COM port
number).
6. Verify the FIFO Enabled check box is checked. If
not, check (enable) it.
7. Exit (return to the Ports dialog box) via two <OK>
command button clicks. Based on past experience,
<Cancel> is not recommended here, even if no
changes of any sort were required within the
Advanced Settings dialog box. If a change is
made, a prompt will appear noting that
Windows NT must be restarted. Do not restart at
this time.
8. From the Ports dialog box, select COM2: in the
Ports: listing.
9. Repeat steps 5 thru 7 for COM2.
10. From the Ports dialog box, select COM3: in the
Ports: listing.
11. Repeat steps 5 thru 7 for COM3.
12. If a change was made in step 6 (for COM1, COM2
and/or COM3), restart Windows NT at this time.
13. Continue with the following start-up procedure.
Since the console application automatically overrides
other serial port settings established within the Ports
program such as baud rate, number of data bits, etc., no
other COM port setting changes are required within the
Ports program.
Starting The Console Application
Start the console application as follows. Factory default
console application start-up settings are assumed:
1. If necessary, from Windows NT Program Manager
restore the C3 Maestro console for Windows NT
program group from an icon state.
2. Execute C3 Maestro’s Dispatch Manager program
by double-clicking its icon (shown below). If no
mouse/track-ball is available, simply use the PC
keyboard’s arrow keys to select the icon (if not
already) and then follow with an <Enter>
keystroke. The Dispatch Manager is the console’s
main on-line program:
Per the factory default configuration, starting the
C3 Maestro’s Dispatch Manager program will
cause it to automatically start two (2) other on-line
programs which are required for (normal) console
operation. The first is the Communications
Interface program; this program handles the serial
control data messages to and from the CIM and
Enhanced Audio Enclosure. The second program is
the GUI—the console’s Graphical User Interface.
3. Continue with the database initialization
procedures which follow.
In some specialized applications, automatic start-up of
the GUI is not desired. See “Start-Up Options” on page 44
for additional information.