AUDIO TOWER REPLACEMENT AE/LZB 119 1894 R1A
35
Table 28 – Dispatch Keyboard Cable
Color Coding
MALE
DIALOG
BOX-9 PIN
NUMBER
CABLE
WIRE
COLOR
USE
1 red dc power
2 white keyboard data
4 green ground
6 (bare) shield
Connect the Dispatch Keyboard to the Enhanced Audio
Enclosure in accordance with subsection entitled
Dispatch Keyboard (if used)” in this manual (page
23).
7. Microphones & Headsets
Connect existing mics and headset jack boxes to the
Enhanced Audio Enclosure per section
INTERCONNECTING THE EQUIPMENT”,
subsection “ENHANCED AUDIO ENCLOSURE” in
this manual (begins on page 23). No wiring changes are
necessary.
8. Footswitches
Audio Tower "FOOTSWITCH 1" should now be used
as an operator footswitch. Connect it to Enhanced
Audio Enclosure's "OPER FT. SW." connector. This
footswitch keys all non-supervisory mics; see the
NOTE on page 24 for microphone priority information.
Also see the subsection entitledFootswitches (if
used)” in this manual (page 24) for additional details.
Audio Tower "FOOTSWITCH 2" should now be used
as a supervisor footswitch. Connect it to Enhanced
Audio Enclosure's "SUPER FT. SW." connector. This
footswitch keys only the supervisor's headset.
9. Speakers
Speakers used with the Audio Tower are un-amplified
units; therefore, they cannot be used with the Enhanced
Audio Enclosure. Speakers used with the Enhanced Audio
Enclosure are amplified units and each includes a volume
control. The Volume Controller Box is not employed in
Enhanced Audio Enclosure applications.
Existing (old) speakers and the Volume Controller Box
were disconnected in step 1. Install and cable the new
Speakers Assemblies (desktop or rack-mount) to the
Enhanced Audio Enclosure in accordance with the
subsection entitled Speakers (if used)” in this manual
(page25).
10. Recorder Outputs
If recorder outputs were utilized in the Audio Tower
installation, rewire these connections to the Enhanced
Audio Enclosure in accordance with the subsection
entitled “Recorder Outputs (if used)” in this manual
(page 25). Audio Tower recorder connections utilized a
large removable terminal block; Enhanced Audio
Enclosure recorder connections utilize a smaller
removable terminal block - the terminal block must be
changed. However, note the pin-out sequence is
identical. Audio Tower I/O Board J1 terminal 1 (top
terminal of "UNSELECT RECORDER" and
"SELECT RECORDER" terminal block) corresponds
to Enhanced Audio Enclosure "RECORDER" terminal
1. Likewise, Audio Tower I/O Board J1 terminal 4
(bottom terminal) corresponds to Enhanced Audio
Enclosure "RECORDER" terminal 4.
11. Paging Inputs
If a pager was utilized with the Audio Tower
installation, rewire these connections to the Enhanced
Audio Enclosure in accordance with the subsection
entitled “External Paging Encoder Input (if used)” in
this manual (page 25). Audio Tower pager connections
utilized a large removable terminal block; Enhanced
Audio Enclosure pager connections utilize a smaller
removable terminal block - the terminal block must be
changed. However, note the pin-out sequence is
identical. Audio Tower I/O Board J2 terminal 1 (top
terminal of "PAGE INPUT" and "PAGE PTT"
terminal block) corresponds to Enhanced Audio
Enclosure "PAGER" terminal 1. Likewise, Audio
Tower I/O Board J2 terminal 4 (bottom terminal)
corresponds to Enhanced Audio Enclosure "PAGER"
terminal 4.
12. Relay Outputs
If any relay outputs were utilized in the Audio Tower
installation, rewire these connections to the Enhanced
Audio Enclosure in accordance with the subsection
entitled “Relay Outputs (if used)” in this manual (page
26).
13. Call Director
If the Audio Tower was connected to a Call Director,
connect the male DB-9 connector on the cable from the
Call Director (disconnected in step 1 from Audio
Tower's I/O Board "CALL DIRECTOR" DB-9) to the
Enhanced Audio Enclosure's female DB-9 "CALL DIR"
connector. See the subsection entitledCall Director
(if equipped)” in this manual (page 26) for additional
details. Line coupling transformers utilized between an
earlier ("Phase 1") Audio Tower and the Call Director
Vista de pagina 34