AUDIO TOWER REPLACEMENT AE/LZB 119 1894 R1A
33
Table 24 – Relay Connections
(18-position terminal block labeled "RELAYS")
TERMINAL NAME*
ACTIVATION
METHOD
1 RELAY_1_NO
console
2 RELAY_1_C PTT
3 RELAY_1_NC
(momentary action)
4 RELAY_2_NO
Dispatch Keyboard
5 RELAY_2_C <Alt><F10>
6 RELAY_2_NC
(momentary action)
7 RELAY_3_NO
Dispatch Keyboard
8 RELAY_3_C <Alt><F9>
9 RELAY_3_NC
(toggle action)
10 RELAY_4_NO
(currently not
11 RELAY_4_C supported
12 RELAY_4_NC
by software)
13 RELAY_5_NO
(currently not
14 RELAY_5_C supported
15 RELAY_5_NC
by software)
16 RELAY_6_NO
(currently not
17 RELAY_6_C supported
18 RELAY_6_NC
by software)
* "NO" = normally-open contact; "C" = common contact;
"NC" = normally-closed contact.
Table 25 – Pager Input
(4-position terminal block labeled "PAGING")
TERMINAL NAME USE
1 PAGER_IN+
balanced
2 PAGER_IN-
audio input
3 PAGER_PTT_IN PTT (enable) input
4 PS_GND_IN ground for pin 3
Table 26 – Recorder Outputs
(4-position terminal block labeled "RECORDER")
TERMINAL NAME USE
1
USEL/TELE_
RECORDER_OUT
unselect recorder
output
2 AGND ground for pin 1
3
SELECT_
RECORDER_OUT
select recorder
audio output
4 AGND ground for pin 3
Table 27 – Auxiliary Audio Inputs (Not Supported)
(1/8-inch stereo phone jack labeled "AUX. IN")
TERMINAL NAME USE
tip AUX_LEFT_IN left chn. input (green)
ring AUX_RIGHT_IN right chn. input (red)
sleeve AUX_IN_GND grounds T and R (black)
AUDIO TOWER REPLACEMENT
NOTE
If installing a completely new C3 Maestro
console system (new PC and new Enhanced
Audio Enclosure equipment), disregard this
section entirely and proceed to the “POWER-
UP PROCEDURE” on page 36.
This section lists the steps necessary to replace earlier
Audio Tower hardware with Enhanced Audio Enclosure
hardware. Instructions are not included on replacing
Personal Computer (PC) hardware and/or software as it is
assumed these items are already Windows NT-ready. To
avoid duplication of information, many references are made
to other Enhanced Audio Enclosure-related installation and
set-up sections within this manual.
1. Power-Down and Cable Disconnections
REMOVE AC POWER from the PC system.
REMOVE AC POWER from the Audio Tower
system.
Disconnect the Dispatch Keyboard from the Logic
Board installed in the PC. If a new keyboard (with
DB-9 connector) is supplied, this old keyboard is no
longer needed.
NOTE