B&B Electronics ESR902 Guía de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
RS910 Ruggedcom Corporation
The RS910 is a serial server that provides
RS-232 to Ethernet conversion and
transport of serial data over an IP
network. Two serial ports are provided
on the unit. The RS910 is also available
in a wireless version, the RS910W, if a
wired connection is not desirable.
Directions included below may also be
found in the RS910 Installation Guide
and the ROS User Guide for
RS910/RS910L/RS910W/RS920L/
RS920W along with more detailed
information about the device. Both
documents are shipped with the RS910
and are available on the Ruggedcom
website at http://www.ruggedcom.com.
Cabling
The
RS910 has two DB-9 connectors on
the front of the unit. Select one for use
with the phase selector. Use the standard
serial cable as described on page 4.
In
addition, this device requires a DB-9
Male to Male adapter and a null modem
adapter to connect the two serial ports
together.
Network Configuration
The RS910 must be setup to ensure the
proper serial port settings are configured
to communicate with the Opticom
Infrared phase selector over the RS-232
interface and that the proper network
configurations are made to allow the
RS910 to be found on the network by
central management software. The unit
must be configured with a static IP
address.
Specify the address type as static.
Specify the IP address to be used by this
device.
Specify the Subnet Mask (usually
255.255.255.0).
Specify the Default Gateway.
Refer to the User’s Guide for instructions
on how to access the configurations via
the internal web pages.
Serial Port Configuration
The Serial Port configuration specifies the
type of transport communications means
which will be used to ferry the RS-232
serial data over the IP network. Central
management software supports TCP
sockets and COM port profiles.
Selection of RawSocket allows the central
management software to connect to the
RS910 via a TCP socket connection.
Installation of Tracer IP COM port
redirector software allows the remote
devices to be installed as COM ports on a
PC or server. Tracer IP is sold separately.
GTT has not tested Tracer IP.
Configure the serial port settings as
described in the Required Serial Settings
on page 3.
Raw Socket Configuration
The transport protocol configuration
defines how the serial data is transported
across the network.
Specify Both for Direction.
Specify TCP for the transport.
Compatibility Test Configuration
Device model: RS910-HI-D-S1-TX01-TX
Device firmware: Boot v2.13.0, Main
v3.5.0
Comm modes: TCP/IP
Software: Central Management Software
1.5
Phase selector: Opticom Infrared Model
752 /754
Vista de pagina 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Comentarios a estos manuales