B&B Electronics ESR902 Guía de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
PortServer
®
TS H MEI
Digi Equipment Corporation
The PortServer TS H MEI is a serial server
that provides RS-232 to Ethernet
conversion and transport of serial data
over an IP network. The PortServer
®
is
available in 1,2 or 4 port versions.
Directions included below may also be
found in the Digi PortServer
®
TS Family
Series Quick Start Guide and the User’s
Guide for Digi One and PortServer
®
TS
Family along with more detailed
information about the device. Both
documents are shipped with the
PortServer
®
and are available on the Digi
website at http://support.digi.com.
Pre-Installation
On the back side of the unit is located a
dip switch for each port. Ensure that the
switch setting indicates RS-232 for the
port to be connected to the phase
selector.
Cabling
The Port Server has RJ45 connectors for
each serial port. For Opticom™ Infrared
System model 752 / 754 phase selectors,
use an RJ45 to 6-pin DIN cable to
connect the two serial ports together.
GTT suggests the STREETCOM EZC-G6D
EZ-Connect cable. Contact STREETCOM
to purchase this cable. The STREETCOM
web site is http://www.streetcom.net
.
Network Configuration
The PortServer
®
must be setup to ensure
the proper serial port settings are
configured to communicate with the
Opticom phase selector over the RS-232
interface and that the proper network
configurations are made to allow the
PortServer
®
to be found on the network
by the central management software. The
unit must be configured with a static IP
address.
Turn off automatic IP address using
DHCP.
Specify the IP address to be used by this
device.
Specify the Subnet Mask (usually
255.255.255.0).
Specify the Default Gateway.
Refer to the PortServer
®
User’s Guide for
instructions on how to access the
configurations via the internal webpages.
Serial Port Configuration
The serial port configuration consists of
selecting the Serial Port Profile and the
Basic Serial Settings.
The Serial Port Profile specifies the type
of transport communications means
which will be used to ferry the RS-232
serial data over the IP network. Central
management software supports TCP
sockets and RealPort profiles.
Installation of Digi’s RealPort COM port
redirector software allows the remote
devices to be installed as COM ports on a
PC or server.
Configure the Basic Serial Settings as
described in the Required Serial Settings
on page 3.
Compatibility Test Configuration
Device model: PortServer
®
TS 4 H MEI
Device firmware: 82000747_U
11/09/2007
Comm modes: TCP/IP, redirected serial
Software: Central Management Software
1.5
Phase selector: Opticom Infrared Model
752 / 754
Vista de pagina 3
1 2 3 4 5 6 7 8 9 ... 14 15