Binary Commands
To Send Binary Commands:
Note: CTS (pin 9) is high when a command is being executed. Hardware
flow control must be disabled as CTS will hold off parameter bytes.
Example: Use binary commands to change the RF module's destination address to
0x1A0D and save the new address to non-volatile memory.
RT Command must be set to '1' in AT Command Mode to enable binary
programming.
Assert CMD (Pin 10 is driven high). (Enter Binary Command Mode)
Send Bytes [parameter bytes must be 2 bytes long]:
(Send DT (Destination Address) Command)
(Least significant byte of parameter bytes)
(Most significant byte of parameter bytes)
(Send WR (Write) Command)
De-assert CMD (pin 10 is driven low). (Exit Binary Command Mode)