40 Manual Documentation Number: ZP24D-250RM-SR-0812
B&B Electronics Mfg Co Inc 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 www.bb-elec.com
B&B Electronics Westlink Commercial Park Oranmore, Galway, Ireland Ph +353 91-792444 Fax +353 91-792445 www.bb-europe.com
CA (CCA Threshold) Command
<RF Interfacing> CA command is used to
set and read CCA (Clear Channel
Assessment) thresholds.
Prior to transmitting a packet, a CCA is
performed to detect energy on the transmit
channel. If the detected energy is above
the CCA Threshold, the RF module will not
transmit the packet.
CC (Command Sequence Character)
Command
<AT Command Mode Options> The
CC command is used to set and read
the ASCII character used between
guard times of the AT Command Mode
Sequence (GT + CC + GT). This sequence enters the RF module into AT Command
Mode so that data entering the module from the host is recognized as commands
instead of payload.
The AT Command Sequence is explained further in the AT Command Mode section.
CE (Coordinator Enable) Command
<Serial Interfacing> The CE command is
used to set and read the behavior (End
Device vs. Coordinator) of the RF module.
AT Command: ATCA
Parameter Range: 0 - 0x50 [-
dBm]
Default Parameter Value: 0x2C
(-44 decimal dBm)
Minimum Firmware Version
Required: v1.x80
AT Command: ATCC
Parameter Range: 0 - 0xFF
Default Parameter Value: 0x2B (ASCII
“+”)
Related Command: GT (Guard Times)
AT Command: ATCE
Parameter Range:0 - 1
Parameter
Configuration
0
End Device
1
Coordinator
Default Parameter Value:0
Minimum Firmware Version Required:
v1.x80