18 Documentation Number: ESP901-2303 Manual
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445
3. When the COMInst window opens select COM port # to map the serial
server to. The default Flow Control setting is None. An RTS/CTS option is
available if used by the application program and serial hardware. The
Protocol, IP Address, and Port Number will mirror the settings of the
selected serial server.
If any settings are changed in this part of the Virtual COM setup it will only
affect the settings in the operating system Device Manager. It will not change
the settings in the ESP901.
The settings of the Virtual COM port in the Device Manager and the ESP901
Configuration menu must match. If the settings do not, the software
connecting to the Virtual COM port will be unsuccessful in opening the
COM port. Highlight the desired COM port # and select OK.