B&B Electronics Zlinx ZP Series Manual de usuario Pagina 3

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 2
Hooking up 3 Zlinx_4107 - 3/12
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com orders@bb-elec.com [email protected]
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
www.bb-europe.com orders@bb-europe.com support@bb-europe.com
PRODUCT INFORMATION B&B ELECTRONICS
For example if you set the Network ID on the I/O radio to 17, you would set the Modem VID to 11 in the
serial radio modem.
The Zlinx I/O radio can be set from (17-255--Decimal)
Here is a chart up to 88 Decimal
Decimal
for Zinx
I/O
Radio
Hex for
Zinx
Serial
Radio
Decimal
for Zinx
I/O
Radio
Hex for
Zinx
Serial
Radio
Decimal
for Zinx
I/O
Radio
Hex for
Zinx
Serial
Radio
17 11 41 29 65 41
18 12 42 2A 66 42
19 13 43 2B 67 43
20 14 44 2C 68 44
21 15 45 2D 69 45
22 16 46 2E 70 46
23 17 47 2F 71 47
24 18 48 30 72 48
25 19 49 31 73 49
26 1A 50 32 74 4A
27 1B 51 33 75 4B
28 1C 52 34 76 4C
29 1D 53 35 77 4D
30 1E 54 36 78 4E
31 1F 55 37 79 4F
32 20 56 38 80 50
33 21 57 39 81 51
34 22 58 3A 82 52
35 23 59 3B 83 53
36 24 60 3C 84 54
37 25 61 3D 85 55
38 26 62 3E 86 56
39 27 63 3F 87 57
40 28 64 40 88 58
13. Click on Terminal tab
14. Type +++ (You will see an OK)
15. Type ATID## **Note: ## = Hex character of radio ID.
We will use 17 for this setup so type ATID17, hit enter, you will see an OK
16. Type ATWR (This writes it to the radio modem—you will see an OK)
17. Go to the Modem Configuration tab and do a Read
Note: The first field is the Modem VID and it should read 17
Vista de pagina 2
1 2 3 4 5 6 7 8 ... 11 12

Comentarios a estos manuales

Sin comentarios