10 HDV100A3 Command & Response Manual
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Byte
Number
Byte
Value
Function
1
01
Start of frame
2
02
Number of control bytes
3
08
ID byte 08 = internal command
4
20
Function code 20 = stop time stamping
5
00
Number data bytes
6
2B
Checksum
To resume time stamping send the following command:
Byte
Number
Byte
Value
Function
1
01
Start of frame
2
02
Number of control bytes
3
08
ID byte 08 = internal command
4
10
Function code 10 = resume time stamping
5
00
Number data bytes
6
1B
Checksum
Time stamping will resume after reset.